Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 10, 2021, 10:21 AM
  • 20 0267_20 0196_02102021_022550.mp4

Date
02/10/2021
W/O
875315
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00739
PipeID
P19121
Time
2:21 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8563
Sewer Name
20 OUTFALL TRUNK
City
PALMDALE
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 20
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_875315_TV20060_FEB2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
20 0196
Downstream MH
20 0267
Dir. of Survey
Upstream
Length Surveyed
30.4 ft.
Total Length
30.4 ft.
Structural Index
3
Structural Quick
3600
Structural Rating
18
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
18
Pipe schematic from manhole 20 0196 to 20 0267
MH: 20 0196MH: 20 0267upstream0 ft. SAP - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 20 02670 ft. MGO - General Observation - STOP LOG AT MOUTH OF PIPE.28.4 ft. SAP - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start30.4 ft. AMH - Downstream Manhole, Survey Begins - 20 019630.4 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - STOP LOG AT MOUTH OF PIPE.

    30.4 ft. - General Observation - STOP LOG AT MOUTH OF PIPE.

Observations (6)

DistanceCodeObservation
2SAP
0AMH20 0196
30.4SAP
30.4AMH20 0267
30.4MGOSTOP LOG AT MOUTH OF PIPE.
0MWL

Properties (7)

additional_info
630069020921202
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2021-02-10T02:21:57-08:00
documentation
PRO PIPE
is_lateral_inspection
false