Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2021, 07:11 AM
  • 29 0255_29 0254_02182021_232850.mp4

Date
02/18/2021
W/O
875065
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00544
PipeID
P24158
Time
11:11 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8610
Sewer Name
29 WEST HILL STREET TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
WO_875065_TV29089_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
29 0255
Downstream MH
29 0254
Dir. of Survey
Downstream
Length Surveyed
158.9 ft.
Total Length
158.9 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
78
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
78
Pipe schematic from manhole 29 0255 to 29 0254
MH: 29 0255MH: 29 0254downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 02550 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area19.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES29.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start88.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"93.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"123.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"147.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"155 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish158.4 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK158.9 ft. AMH - Downstream Manhole, Survey Ends - 29 0254

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    19.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    29.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
158.4MGOCONNECTION AT MH, 3 O'CLOCK
158.9AMH29 0254
123.2TFC
147.3TFC
93.6TFC
0AMH29 0255
0MWL
0MWM
88.1TFC
155CM
29.2CM
19.7CM

Properties (6)

custom_field_three
CRACKS
custom_field_two
2
customer
1
datetime
2021-02-18T23:11:49-08:00
documentation
PRO PIPE
is_lateral_inspection
false