Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 2, 2021, 05:27 PM
  • J 0215_J 0214_422021_120314.mp4

Date
04/02/2021
W/O
0879983
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00057
PipeID
P11459
Time
10:27 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1765
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
48
Purpose
Capital Improvement Program Assesment
Project
20210402SHO_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0215
Downstream MH
J 0214
Dir. of Survey
Downstream
Length Surveyed
427.7 ft.
Total Length
427.7 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole J 0215 to J 0214
MH: J 0215MH: J 0214downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 2150 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area7.4 ft. MGO - General Observation - 90% MAG COAT INTACT7.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start424.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish427.7 ft. AMH - Downstream Manhole, Survey Ends - J 214

Observations (7)

DistanceCodeObservation
427.7AMHJ 214
0AMHJ 215
7.4MGO90% MAG COAT INTACT
424.1SSS
7.4SSS
0MWL
0MWM

Properties (6)

additional_info
RFIR
custom_field_two
3
customer
LACSD
datetime
2021-04-02T10:27:51-07:00
documentation
OBREGON, SHADLER, BRAR, RAMIREZ
is_lateral_inspection
false