Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2021, 12:30 PM
  • 04 0079_04 0078A_02222021_044805.mp4

Date
02/22/2021
W/O
875394
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11817
Time
4:30 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8579
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
RFIR_WO_875394_TV04009_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
04 0079
Downstream MH
04 0078A
Dir. of Survey
Downstream
Length Surveyed
318.2 ft.
Total Length
318.2 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
113
O&M Index
2
O&M Quick
312X
O&M Rating
256
Overall Index
2
Overall Quick
Overall Rating
369
Pipe schematic from manhole 04 0079 to 04 0078A
MH: 04 0079MH: 04 0078Adownstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 04 00792 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.6 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start36.4 ft. RML - Roots Medium Lateral, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES36.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"38.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"82.6 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"84.5 ft. RFL - Roots Fine Lateral, from 08 to 11 o'clock84.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"122.8 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"133.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"134.2 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES137.8 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"147.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start176.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES180.7 ft. RFB - Roots Fine Barrell, at 08 o'clock, within 8 inches of joint: YES182.9 ft. HSV - Hole Soil Visible, from 10 to 11 o'clock, within 8 inches of joint: YES191.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"214.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"223 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"256 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"269.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"314.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"316.7 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish316.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish316.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"316.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish318.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE318.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK318.2 ft. AMH - Downstream Manhole, Survey Ends - 04 0078A

Observation photos (11)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    6.6 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES

    36.4 ft. - Roots Medium Lateral, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Fine Lateral, from 08 to 11 o'clock

    84.5 ft. - Roots Fine Lateral, from 08 to 11 o'clock

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    134.2 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    147.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    177.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Barrell, at 08 o'clock, within 8 inches of joint: YES

    180.7 ft. - Roots Fine Barrell, at 08 o'clock, within 8 inches of joint: YES

  • Hole Soil Visible, from 10 to 11 o'clock, within 8 inches of joint: YES

    182.9 ft. - Hole Soil Visible, from 10 to 11 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    318.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (34)

DistanceCodeObservation
176.8TFA
269.2TFC
316.7DAE
0MGOCOCKROACHES IN MANHOLE
316.7DAGS
137.8TFA
316.7TFA
318.2MGOCOCKROACHES IN MANHOLE
318.2MGOCONNECTION AT MH 9 O'CLOCK
223TBA
6.6DAE
191.7TFA
0MWL
133.4TFA
316.7CM
134.2CL
82.6TFA
84.5RFL
36.4RML
256TFA
314.7TFC
214.4TFA
147.7CM
38.5TFA
177.7FM
2DAGS
122.8TFA
84.5TFA
318.2AMH04 0078A
180.7RFB
36.4TFA
182.9HSV
0MWM
0AMH04 0079

Properties (7)

additional_info
630069022221001
custom_field_three
FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2021-02-22T04:30:04-08:00
documentation
PRO PIPE
is_lateral_inspection
false