Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2021, 09:51 AM
  • 04 0070_04 0069A_02222021_020749.mp4

Date
02/22/2021
W/O
875394
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11806
Time
1:51 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8579
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
RFIR_WO_875394_TV04009_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
04 0069A
Downstream MH
04 0070
Dir. of Survey
Upstream
Length Surveyed
302.6 ft.
Total Length
302.6 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
2
O&M Quick
312K
O&M Rating
127
Overall Index
2
Overall Quick
Overall Rating
134
Pipe schematic from manhole 04 0069A to 04 0070
MH: 04 0069AMH: 04 0070upstream0 ft. AMH - Upstream Manhole, Survey Ends - 04 00700 ft. MGO - General Observation - COCKROACHES IN MANHOLE2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish30.6 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6", 6"43.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.5 ft. IW - Infiltration Weeper, at 12 o'clock, within 8 inches of joint: YES69.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"95.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"109.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"119 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"119.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES121.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"150 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES160.2 ft. IW - Infiltration Weeper, at 10 o'clock, within 8 inches of joint: YES179.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"197.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES197.9 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"245.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"250.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"271.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"271.7 ft. H - Hole, at 10 o'clock, within 8 inches of joint: NO274 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start302.6 ft. AMH - Downstream Manhole, Survey Begins - 04 0069A302.6 ft. MWL - Water Level, 5 %of cross sectional area302.6 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Hole, at 10 o'clock, within 8 inches of joint: NO

    30.9 ft. - Hole, at 10 o'clock, within 8 inches of joint: NO

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    104.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Weeper, at 10 o'clock, within 8 inches of joint: YES

    142.4 ft. - Infiltration Weeper, at 10 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    152.6 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    182.8 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Infiltration Weeper, at 12 o'clock, within 8 inches of joint: YES

    236.1 ft. - Infiltration Weeper, at 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    302.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (26)

DistanceCodeObservation
123.1TFC
0AMH04 0069A
272TFA
0MWL
181.3TFA
0MWM
207TFA
302.6AMH04 0070
142.4IW
193.5TFA
232.9TFA
104.7CL
2DAGS
236.1IW
52.4TFA
104.7TFA
28.6TFC
152.6ID
30.9H
182.8CL
183.6TFA
31.3TFC
57.3TFC
302.6MGOCOCKROACHES IN MANHOLE
259TFA
299.9DAGS

Properties (7)

additional_info
630069022221001
custom_field_three
CRACKS/HOLE
custom_field_two
2
customer
1
datetime
2021-02-22T01:51:28-08:00
documentation
PRO PIPE
is_lateral_inspection
false