Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2021, 09:16 AM
  • 04 0068_04 0047_02222021_014036.mp4

Date
02/22/2021
W/O
875394
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11803
Time
1:16 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8579
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
RFIR_WO_875394_TV04009_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
04 0068
Downstream MH
04 0047
Dir. of Survey
Downstream
Length Surveyed
325.9 ft.
Total Length
325.9 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
18
O&M Index
2
O&M Quick
312U
O&M Rating
226
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole 04 0068 to 04 0047
MH: 04 0068MH: 04 0047downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04 00680 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start4.5 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start14.5 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish21.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"31.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"58.5 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR61.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"85 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS131.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"133 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES140.4 ft. DSC - Deposits Settled Compacted, 15 %of cross sectional area, from 06 to 09 o'clock, , within 8 inches of joint: YES140.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"179.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"206.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"218.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.2 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES259 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"262.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES262.4 ft. IW - Infiltration Weeper, at 03 o'clock, within 8 inches of joint: YES294.7 ft. MGO - General Observation - RUN LIST STATES MH AT 295'.294.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES324 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish324 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish325.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE325.9 ft. MGO - General Observation - CONNECTIONS IN MH AT BOTH 12 AND 9 O' CLOCK325.9 ft. AMH - Downstream Manhole, Survey Ends - 04 0047

Observation photos (12)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

    58.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - DEBRIS

    95.9 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    133 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Settled Compacted,  15 %of cross sectional area, from 06 to 09 o'clock,  , within 8 inches of joint: YES

    140.4 ft. - Deposits Settled Compacted, 15 %of cross sectional area, from 06 to 09 o'clock, , within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    234.2 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    262.4 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Infiltration Weeper, at 03 o'clock, within 8 inches of joint: YES

    262.4 ft. - Infiltration Weeper, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    294.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    325.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (33)

DistanceCodeObservation
262.4CL
31.7TFA
0AMH04 0068
140.4DSC
140.5TFC
325.9MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE
21.5TF
0MGOCONNECTION AT MH 9 O'CLOCK
325.9MGOCONNECTIONS IN MH AT BOTH 12 AND 9 O' CLOCK
294.7MGORUN LIST STATES MH AT 295'.
325.9AMH04 0047
324DAGS
262.4IW
85TFC
194.6TBA
294.7CM
179.8TF
2DAGS
0MWM
131.1TBA
133CM
324DSZ
206.3TFC
95.9DSZDEBRIS
58.5RFJ
61.6TF
234.2CL
4.5FM
218.8TFC
14.5FM
0MWL
259TF

Properties (7)

additional_info
630069022221001
custom_field_three
MULTIPLE FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2021-02-22T01:16:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false