Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 24, 2021, 06:45 PM
  • 21 1127_21 1126_02242021_104905.mp4

Date
02/24/2021
W/O
875040
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00780
PipeID
P16221
Time
10:45 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8607
Sewer Name
21 POMONA BOULEVARD INTERCEPTOR TRUNK
City
POMONA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_875040_TV21085_FEB2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
21 1127
Downstream MH
21 1126
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 21 1127 to 21 1126
MH: 21 1127MH: 21 1126downstream0 ft. AMH - Upstream Manhole, Survey Begins - 21 11272 ft. MSA - Survey Abandoned - UNABLE TO ACCESS DUE TO DIVERSION PLATE.2 ft. MGO - General Observation - NO REVERSAL POSSIBLE. D/S MH IS BURIED.2 ft. MGO - General Observation - DIVERSION PLATE.

Observation photos (2)

  • Survey Abandoned - UNABLE TO ACCESS DUE TO DIVERSION PLATE.

    2 ft. - Survey Abandoned - UNABLE TO ACCESS DUE TO DIVERSION PLATE.

  • General Observation - DIVERSION PLATE.

    2 ft. - General Observation - DIVERSION PLATE.

Observations (4)

DistanceCodeObservation
2MSAUNABLE TO ACCESS DUE TO DIVERSION PLATE.
2MGONO REVERSAL POSSIBLE. D/S MH IS BURIED.
0AMH21 1127
2MGODIVERSION PLATE.

Properties (7)

custom_field_three
no access
custom_field_two
5
customer
1
datetime
2021-02-24T10:45:29-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
30721