Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2021, 07:08 AM
  • H 0112_H 0111_02172021_000727.mp4

Date
02/16/2021
W/O
875062
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00165
PipeID
P10563
Time
11:08 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8573
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_875062_TV01242_FEB2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
H 0112
Downstream MH
H 0111
Dir. of Survey
Downstream
Length Surveyed
423.4 ft.
Total Length
423.4 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
420
O&M Index
2
O&M Quick
2P00
O&M Rating
168
Overall Index
2
Overall Quick
Overall Rating
588
Pipe schematic from manhole H 0112 to H 0111
MH: H 0112MH: H 0111downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 01120 ft. MGO - General Observation - 35% MAG COAT0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start68.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"423.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish423.4 ft. MSA - Survey Abandoned - REDUCED FLOW. WILL ZOOM IN FROM D/S MH.423.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish423.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (5)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - REDUCED FLOW. WILL ZOOM IN FROM D/S MH.

    423.4 ft. - Survey Abandoned - REDUCED FLOW. WILL ZOOM IN FROM D/S MH.

Observations (13)

DistanceCodeObservation
0AMHH 0112
423.4SSS
68.9TFA
0MGO35% MAG COAT
2SSS
423.4MSAREDUCED FLOW. WILL ZOOM IN FROM D/S MH.
423.4SAP
0MGOROACHES @ MH
2SAP
2DAGS
0MWL
423.4DAGS
0MWM

Properties (7)

additional_info
630069021621201
custom_field_three
ABANDONED DUE TO REDUCED FLOW. NEED REVERSAL.
custom_field_two
5
customer
1
datetime
2021-02-16T23:08:42-08:00
documentation
PRO PIPE
is_lateral_inspection
false