- Date
- 02/17/2021
- W/O
- 875062
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00165
- PipeID
- P10560
- Time
- 12:46 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8573
- Sewer Name
- H JOINT OUTFALL H - UNIT 1F
- City
- HUNTINGTON PARK
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- RFIR_WO_875062_TV01242_FEB2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 36 in.
- Upstream MH
- H 0109
- Downstream MH
- H 0108
- Dir. of Survey
- Downstream
- Length Surveyed
- 57.9 ft.
- Total Length
- 57.9 ft.
- Structural Index
- 3
- Structural Quick
- 523A
- Structural Rating
- 60
- O&M Index
- 2
- O&M Quick
- 2A00
- O&M Rating
- 22
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 82
Pipe schematic from manhole H 0109 to H 0108 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

8.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

43.3 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

57.9 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES