Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2021, 11:38 AM
  • 01 0802_01 1375_02182021_034245.mp4

Date
02/18/2021
W/O
875316
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00197
PipeID
P21617
Time
3:38 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8576
Sewer Name
01 BULLIS ROAD-TEMPLE STREET TRUNK
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_875316_TV01264_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0802
Downstream MH
01 1375
Dir. of Survey
Downstream
Length Surveyed
28.6 ft.
Total Length
28.6 ft.
Structural Index
3
Structural Quick
4134
Structural Rating
16
O&M Index
2
O&M Quick
4125
O&M Rating
14
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 01 0802 to 01 1375
MH: 01 0802MH: 01 1375downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 08022 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start23.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES23.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish27.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish28.6 ft. AMH - Downstream Manhole, Survey Ends - 01 1375

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    23.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
28.6AMH01 1375
0MWM
23.2FM
0MWL
27.6DAGS
0AMH01 0802
2DAGS
2FL
23.2FL

Properties (7)

additional_info
630069021721203
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-02-18T03:38:28-08:00
documentation
PRO PIPE
is_lateral_inspection
false