Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2021, 06:49 AM
  • 05 1913_05 2645_02102021_230356.mp4

Date
02/10/2021
W/O
875147
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00501
PipeID
P26137
Time
10:49 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8474
Sewer Name
05 PALOS VERDES NORTH SLOPE TRUNK, SECT 1
City
LOMITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_875147_TV05312_FEB2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1913
Downstream MH
05 2645
Dir. of Survey
Downstream
Length Surveyed
375.7 ft.
Total Length
375.7 ft.
Structural Index
3
Structural Quick
4N3N
Structural Rating
665
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
667
Pipe schematic from manhole 05 1913 to 05 2645
MH: 05 1913MH: 05 2645downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 19132.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.2 ft. RFC - Roots Fine Connection, at 10 o'clock7.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE8.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE100 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE152 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE208.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"243.7 ft. RFL - Roots Fine Lateral, at 12 o'clock243.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"279.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE375.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375.7 ft. AMH - Downstream Manhole, Survey Ends - 05 2645

Observation photos (5)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    7.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE

    45.7 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE

Observations (19)

DistanceCodeObservation
279.6TFACTIVE
7.2RFC
375.7SAP
0MWM
152TFAPPARENTLY ACTIVE
375.7SSS
8.3FM
0MWL
375.7FM
45.7TBAPPARENTLY ACTIVE
0AMH05 1913
2.5SAP
243.7RFL
100TFAPPARENTLY ACTIVE
375.7AMH05 2645
3.5SSS
7.2TBACTIVE
243.7TF
208.8TFA

Properties (8)

additional_info
630074021021202
custom_field_three
AGGREGATE PROJECTING/SPALLING/MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-02-10T22:49:39-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
39052