Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2021, 06:02 AM
  • 05 2663_05 1916_02102021_221612.mp4

Date
02/10/2021
W/O
875147
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00501
PipeID
P07144
Time
10:02 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8474
Sewer Name
05 PALOS VERDES NORTH SLOPE TRUNK, SECT 1
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_875147_TV05312_FEB2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
05 1916
Downstream MH
05 2663
Dir. of Survey
Upstream
Length Surveyed
373.9 ft.
Total Length
373.9 ft.
Structural Index
3
Structural Quick
453N
Structural Rating
393
O&M Index
1
O&M Quick
1A00
O&M Rating
11
Overall Index
2
Overall Quick
Overall Rating
404
Pipe schematic from manhole 05 1916 to 05 2663
MH: 05 1916MH: 05 2663upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 26630 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish102.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES121 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES133.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish186.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start186.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES237.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES351.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES369.5 ft. FL - Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES370 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start371.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start373.9 ft. MWM - Water Mark, 5 %of cross sectional area373.9 ft. MWL - Water Level, 5 %of cross sectional area373.9 ft. AMH - Downstream Manhole, Survey Begins - 05 1916

Observation photos (9)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES

    4.4 ft. - Fracture Longitudinal, at 07 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    22 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    136.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    187.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    187.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    252.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    271.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
271.8FM
373.8SSS
252.9FM
2.8SAP
373.9AMH05 2663
187.4FM
22FM
136.7FM
4.4FL
0MWM
187.5RFJ
240.5RFJ
0MWL
3.9SSS
373.9SAP
0AMH05 1916

Properties (7)

additional_info
630074021021202
custom_field_three
AGGREGATE PROJECTING/SPALLING/MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-02-10T22:02:10-08:00
documentation
PROPIPE
is_lateral_inspection
false