05 1915_05 1914_02102021_223923.mp4
2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
14.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, 6ft
14.6 ft. - Roots Fine Joint, from 08 to 03 o'clock, within 8 inches of joint: YES
89.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
148.7 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
242.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
360.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY RECENT: ACTIVE FLOW
| Distance | Code | Observation |
|---|---|---|
| 14.6 | FM | — |
| 148.7 | RFJ | — |
| 0 | MWM | — |
| 381.7 | SSS | — |
| 242.7 | FM | — |
| 2.1 | SSS | — |
| 381.7 | SAP | — |
| 2.1 | SAP | — |
| 381.7 | FM | — |
| 14.6 | RFJ | — |
| 381.7 | AMH | 05 1914 |
| 360.7 | TB | APPARENTLY RECENT: ACTIVE FLOW |
| 89.2 | FM | — |
| 381.7 | RFJ | — |
| 0 | AMH | 05 1915 |
| 0 | MWL | — |