- Date
- 03/02/2021
- W/O
- 875026
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00087
- PipeID
- P08824
- Time
- 3:27 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8626
- Sewer Name
- B JOINT OUTFALL B - UNIT 3A RELIEF
- City
- EL MONTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_875026_TV15104_FEB2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 24 in.
- Upstream MH
- B 0333
- Downstream MH
- B 0332
- Dir. of Survey
- Downstream
- Length Surveyed
- 31.8 ft.
- Total Length
- 31.8 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole B 0333 to B 0332 Observation photos (2)

12.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

18.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start