Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 10, 2021, 11:13 AM
  • 22 0320_22 0233_02102021_032009.mp4

Date
02/10/2021
W/O
870227
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00793
PipeID
P16515
Time
3:13 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8400
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_870227_TV22131_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
22 0233
Downstream MH
22 0320
Dir. of Survey
Upstream
Length Surveyed
7.6 ft.
Total Length
7.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 22 0233 to 22 0320
MH: 22 0233MH: 22 0320upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 03200 ft. MGO - General Observation - ACTIVE CONNECTION AT MH, 9 O'CLOCK5.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES7.6 ft. MWM - Water Mark, 35 %of cross sectional area7.6 ft. AMH - Downstream Manhole, Survey Begins - 22 02337.6 ft. MWL - Water Level, 15 %of cross sectional area7.6 ft. MGO - General Observation - CONNECTION AT MH, 3 AND 9 O'CLOCK - UNKNOWN FLOW STATUS FOR BOTH

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MWM
0AMH22 0233
0MWL
0MGOCONNECTION AT MH, 3 AND 9 O'CLOCK - UNKNOWN FLOW STATUS FOR BOTH
7.6AMH22 0320
2.4DAGS
7.6MGOACTIVE CONNECTION AT MH, 9 O'CLOCK

Properties (6)

custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-02-10T03:13:28-08:00
documentation
PRO PIPE
is_lateral_inspection
false