- Date
- 05/02/2016
- W/O
- 0563839
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00016
- PipeID
- P00002
- Time
- 1:26 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6698
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160430MDM_MAIN_STREET_TRUNK
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- 08 0591
- Downstream MH
- 08 0683
- Dir. of Survey
- Upstream
- Length Surveyed
- 12.7 ft.
- Total Length
- 12.7 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 08 0591 to 08 0683 Observation photos (4)

2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG 1'

3 ft. - General Observation - ALL TILES IN PLACE START

12.5 ft. - General Observation - TILES 100% IN PLACE FINISH

12.7 ft. - Upstream Manhole, Survey Ends - 5:35AM-ZOOM 12:.5'