2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG AREAS OF MISSING TILES
2 ft. - General Observation - MISSING TILES 80% START 10:00 TO 2:00
15.2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
17.4 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM
24.1 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
29.9 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM
32.4 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM
38.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
47.6 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM
59.8 ft. - General Observation - MISSING TILES 60% START
73.9 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CICRUM REBAR
111.4 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM
129.3 ft. - General Observation - MISSING TILES 30%
140.5 ft. - General Observation - MISSING TILES 80% START
142.5 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM SPORATIC
160 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR
174.9 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
186.8 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR
235.5 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR
| Distance | Code | Observation |
|---|---|---|
| 0 | MGO | MH CONN ACTIVE 3:00 |
| 0 | AMH | 4:20AM |
| 17.4 | SRV | CIRCUM |
| 129.3 | MGO | MISSING TILES 30% |
| 111.4 | SRC | CIRCUM |
| 174.9 | SRC | CIRCUM REBAR |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 47.6 | SRC | CIRCUM |
| 142.5 | SRV | CIRCUM SPORATIC |
| 140.5 | MGO | MISSING TILES 80% START |
| 59.8 | MGO | MISSING TILES 60% START |
| 15.2 | SAV | SEVERE AGG |
| 24.1 | SRV | CIRCUM REBAR |
| 268.5 | SRV | CIRCUM REBAR |
| 32.4 | SRV | CIRCUM |
| 29.9 | SRV | CIRCUM |
| 0 | MWM | — |
| 268.9 | AMH | 4:50AM |
| 268.5 | SAM | SEVERE AGG |
| 268.5 | MGO | MISSING TILES 80% FINISH |
| 73.9 | SRV | LONG CICRUM REBAR |
| 235.5 | SRV | LONG REBAR |
| 59.8 | SRC | LONG CIRCUM REBAR |
| 0 | MWL | — |
| 0 | MGO | MH CONN ACTIVE 9:00 |
| 117.6 | SRC | — |
| 2 | MGO | MISSING TILES 80% START 10:00 TO 2:00 |
| 186.8 | SRC | LONG CIRCUM REBAR |
| 160 | SRV | LONG CIRCUM REBAR |
| 38.1 | SRC | LONG CIRCUM REBAR |