- Date
- 04/30/2016
- W/O
- 0563300
- Weather
- Light Rain
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00689
- PipeID
- P13865
- Time
- 7:14 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7102
- Sewer Name
- 18 MILLS AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- 20160428AM_MILLS_AVENUE_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 18 0050
- Downstream MH
- 18 0049
- Dir. of Survey
- Downstream
- Length Surveyed
- 196.1 ft.
- Total Length
- 196.1 ft.
- Structural Index
- 3
- Structural Quick
- 4232
- Structural Rating
- 18
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole 18 0050 to 18 0049 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

48.6 ft. - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

103.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

139.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

152.7 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, HOLE IN THE PIPE