Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2016, 09:11 AM
  • 05 0700_05 0699_4272016_022704.mp4

Date
04/27/2016
W/O
0558014
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00523
PipeID
P05932
Time
2:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0115
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20160427MDM_SOUTH_INGLEWOOD_ORANGE_AVENUE_TRUNK_EXTENSION_2
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
05 0699
Downstream MH
05 0700
Dir. of Survey
Upstream
Length Surveyed
222.7 ft.
Total Length
222.7 ft.
Structural Index
2
Structural Quick
443F
Structural Rating
222
O&M Index
3
O&M Quick
4231
O&M Rating
15
Overall Index
2
Overall Quick
Overall Rating
237
Pipe schematic from manhole 05 0699 to 05 0700
MH: 05 0699MH: 05 0700upstream0 ft. AMH - Upstream Manhole, Survey Ends-COMLETED REVERESE INSPECTION - 3:55AM-INSPECTIN COMPLETED REVERSE INSPECTION0.4 ft. MGP - General Photograph - ROCK & MEDUM OFFSET JOINT0.4 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - ROCK OR ASPHALT-PAPER DEBRIE4 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT11.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open12.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H15.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT15.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H18.7 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H21.9 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H21.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT24.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H28.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H28.9 ft. MWL - Water Level, 50 %of cross sectional area34.1 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SLIGHT37.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SLIGHT37.1 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SLIGHT40 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT40 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SLIGHT43.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT43.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT46.2 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT49.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT52.3 ft. JSM - Joint Separated Medium - THROUGHOUT REACH55.2 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H58.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT59.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped60.9 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H60.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H60.9 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - MODERATE61.5 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped62.4 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT63.6 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 5" - Open63.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H64 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H70.2 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT70.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT73.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT76.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT76.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H79.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SLIGHT79.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT82.4 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H82.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT85.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H88.4 ft. MWM - Water Mark, 20 %of cross sectional area88.4 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H91.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT94.5 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - SLIGHT94.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT94.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H97.7 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT97.7 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H100.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT100.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT103.8 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - SLIGHT103.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H103.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT106.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT106.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H109.8 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT110.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped112.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H115.6 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT115.6 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H121.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT127.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT130.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT134 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT134 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H137 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H137 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H139.9 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT139.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H139.9 ft. MWM - Water Mark, 30 %of cross sectional area143.2 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H149.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT152.4 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H155.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H155.5 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - H158.4 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT162.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped164.1 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H167 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES167 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SLIGHT167 ft. MWM - Water Mark, 50 %of cross sectional area170.4 ft. FC - Fracture Circumferential, from 12 to 05 o'clock, within 8 inches of joint: YES - SLIGHT172.7 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H172.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H174 ft. JOM - Joint Offset Medium - SLIGHT & MEDUIUM THROUGHOUT REACH176.2 ft. MWM - Water Mark, 30 %of cross sectional area176.2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - SLIGHT176.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT179.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT185.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H188.6 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H191.9 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H194.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT194.8 ft. MGO - General Observation - 8" VCP196.2 ft. MWM - Water Mark, 50 %of cross sectional area198 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H203.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT203.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H207.1 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE207.1 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SLIGHT210.3 ft. FC - Fracture Circumferential, from 08 to 03 o'clock, within 8 inches of joint: YES - SLIGHT211.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped214.8 ft. FC - Fracture Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES - SLIGHT218.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT222.7 ft. MWL - Water Level, 10 %of cross sectional area222.7 ft. MWM - Water Mark, 30 %of cross sectional area222.7 ft. AMH - Downstream Manhole, Survey Begins - 2:25AM

Observation photos (9)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

    27.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

  • General Observation - 8" VCP

    27.9 ft. - General Observation - 8" VCP

  • Joint Offset Medium - SLIGHT & MEDUIUM THROUGHOUT REACH

    48.7 ft. - Joint Offset Medium - SLIGHT & MEDUIUM THROUGHOUT REACH

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

    73.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

    101 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped

    161.2 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped

  • Joint Separated Medium - THROUGHOUT REACH

    170.4 ft. - Joint Separated Medium - THROUGHOUT REACH

  • General Photograph - ROCK & MEDUM OFFSET JOINT

    222.3 ft. - General Photograph - ROCK & MEDUM OFFSET JOINT

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - ROCK OR ASPHALT-PAPER DEBRIE

    222.3 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - ROCK OR ASPHALT-PAPER DEBRIE

Observations (112)

DistanceCodeObservation
173.6FLSLIGHT
200.8FCH
88.7FLSLIGHT
112.9FCSLIGHT
70.3FCH
118.9FLSLIGHT
176.5FCSLIGHT
128.2FLSLIGHT
27.9FMSLIGHT
48.7JOMSLIGHT & MEDUIUM THROUGHOUT REACH
0MWL
198.1FCH
115.8FCSLIGHT
24.7FCH
164.3FLSLIGHT
73.5FMSLIGHT
85.7FLH
170.4JSMTHROUGHOUT REACH
146.4FCSLIGHT
67.2FLH
211.3TFOpen
149.4FLSLIGHT
15.6FCHAIRLINE
82.8FCSLIGHT
160.3FCSLIGHT
91.9FLSLIGHT
159.1TBOpen
27.9MGO8" VCP
134.3MWM
0MWM
143.5FLSLIGHT
182.7FLSLIGHT
11.5TFCCapped
12.4FCSLIGHT
30.8FCH
46.2FCSLIGHT
161.2TBCCapped
204FCH
122.1FLSLIGHT
26.5MWM
112.1TFCCapped
222.3MGPROCK & MEDUM OFFSET JOINT
50FCH
193.8FLH
167.5FCH
179.6FLSLIGHT
82.8FCH
115.8FCH
88.7FCH
200.8FLSLIGHT
107.1FCSLIGHT
110.2FCH
37.1FCH
18.8FLH
85.7FCH
4FCSLIGHT
60.5TFCCapped
185.6FLSLIGHT
95FMSLIGHT
134.3FCH
210.1FLH
82.8MWM
125FCSLIGHT
152.5FCSLIGHT
50FLH
143.5FLSLIGHT
140.3FCH
55.7DAGS
55.7FCSLIGHT
43.2FCSLIGHT
193.8MWL
222.3DSZROCK OR ASPHALT-PAPER DEBRIE
7.9FCSLIGHT
158.7FLH
118.9FCH
46.5MWM
107.1FCH
122.1FLSLIGHT
55.7MWM
161.8FCH
67.2FCH
101FMSLIGHT
128.2FLSLIGHT
159FLH
161.8FCH
46.5FLSLIGHT
15.6FCSLIGHT
52.3FCSLIGHT
58.6FCH
118.9FLSLIGHT
128.2FLH
137.3FLH
222.7AMH3:55AM-INSPECTIN COMPLETED REVERSE INSPECTION
19.2FLSLIGHT
79.5FCH
34.1FLH
125FCH
218.7FCSLIGHT
206.9FLSLIGHT
179.6FCSLIGHT
182.7FCSLIGHT
185.6FCSLIGHT
64.3FCSLIGHT
163.5TFCCapped
146.4FLH
206.9FLH
152.5FCSLIGHT
131.5FCSLIGHT
161.8FCMODERATE
0AMH2:25AM
140.3FLSLIGHT
188.6FCSLIGHT

Properties (6)

custom_field_three
1 MOD FRACTURE-MOD OFFSET&SEPERATED JOINTS
custom_field_two
3
customer
LACSD
datetime
2016-04-27T02:11:27-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false