Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2016, 03:54 PM
  • 18 0377_18 0376_4262016_085733.mp4

Date
04/26/2016
W/O
0563369
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00690
PipeID
P14211
Time
8:54 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7096
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20160422AM_NORTH_NORWALK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
18 0377
Downstream MH
18 0376
Dir. of Survey
Downstream
Length Surveyed
144.9 ft.
Total Length
144.9 ft.
Structural Index
3
Structural Quick
5149
Structural Rating
58
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
64
Pipe schematic from manhole 18 0377 to 18 0376
MH: 18 0377MH: 18 0376downstream0 ft. AMH - Upstream Manhole, Survey Begins - 8:56 AM0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - ROACHES INSIDE THE MH.0 ft. MWM - Water Mark, 65 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK6.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES10 ft. FM - Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES14.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES26.4 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES30.2 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES34.5 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES34.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES39.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"45.8 ft. FM - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES54 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES58 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES62.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start70.4 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES74.4 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES78.5 ft. B - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES82.5 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES91.5 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - CAPPED, CRACKED117.7 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN134.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES143.1 ft. MGO - General Observation - SLIGHT GREASE/DEBRIS THROUGHOUT THE REACH143.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish143.1 ft. MGO - General Observation - MULTIPLE FRACTURES THROUGHOUT THE REACH143.3 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK143.3 ft. MGO - General Observation - ROACHES INSIDE THE MH.143.9 ft. MGO - General Observation - CORRODED CHANNEL144.9 ft. AMH - Downstream Manhole, Survey Ends - 9:22 AM

Observation photos (14)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    6.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

    10 ft. - Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    30.2 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

    34.5 ft. - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    45.8 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    54 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    58 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES

    70.4 ft. - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES

    74.4 ft. - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES

  • Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

    78.5 ft. - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    82.5 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    117.7 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    134.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - CORRODED CHANNEL

    143.9 ft. - General Observation - CORRODED CHANNEL

Observations (31)

DistanceCodeObservation
0AMH8:56 AM
10FM
30.2FM
14.2FM
54FM
0MWL
39.6TFC
62.1CM
26.4CM
134.1FM
74.4FC
143.3MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
34.5FC
143.1MGOSLIGHT GREASE/DEBRIS THROUGHOUT THE REACH
58FM
70.4FC
143.1CM
6.2FM
0MGOROACHES INSIDE THE MH.
91.5TFDCAPPED, CRACKED
143.1MGOMULTIPLE FRACTURES THROUGHOUT THE REACH
143.9MGOCORRODED CHANNEL
117.7FMPOSSIBLY BROKEN
143.3MGOROACHES INSIDE THE MH.
82.5FL
45.8FM
144.9AMH9:22 AM
0MWM
0MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
34.6CL
78.5B

Properties (7)

additional_info
RFIR INSPECTION
custom_field_three
BROKEN PIPE
custom_field_two
1
customer
LACSD
datetime
2016-04-26T08:54:44-07:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false