Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 8, 2016, 10:31 AM
  • 05 1068_05 1067_04082016_Manual.mp4

Date
04/08/2016
W/O
0557603
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00488
PipeID
P06302
Time
3:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6681
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
20160408MDM_MONETA_EXTENSION_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 1068
Downstream MH
05 1067
Dir. of Survey
Downstream
Length Surveyed
271.6 ft.
Total Length
271.6 ft.
Structural Index
2
Structural Quick
2413
Structural Rating
11
O&M Index
2
O&M Quick
412J
O&M Rating
112
Overall Index
2
Overall Quick
Overall Rating
123
Pipe schematic from manhole 05 1068 to 05 1067
MH: 05 1068MH: 05 1067downstream0 ft. MGO - General Observation - MH CONN STUB 3:000 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:35AM2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start8 ft. MGO - General Observation - 24" VCP16.8 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES25.2 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE119.1 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE170 ft. CC - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES261.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES264.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE264.7 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES271.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish271.2 ft. MGO - General Observation - MH CONN ACTIVE 12:00271.6 ft. AMH - Downstream Manhole, Survey Ends - 5:00AM

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
119.1FCHAIRLINE
0MGOMH CONN STUB 3:00
8MGO24" VCP
271.2DAGS
16.8CC
264.7FCHAIRLINE
261.4CL
264.7CC
170CC
271.6AMH5:00AM
0MWL
271.2MGOMH CONN ACTIVE 12:00
0MWM
0AMH4:35AM
25.2FCHAIRLINE
2DAGS

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2016-04-08T03:31:59-07:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false