- Date
- 10/07/2016
- W/O
- 0592184
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00365
- PipeID
- P23122
- Time
- 1:36 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0315
- Sewer Name
- C JOINT OUTFALL C - UNIT 4C RELIEF
- City
- LONG BEACH
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- 20161007MDM_JOINT_OUTFALL_C_UNIT_4C_RELIEF
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- C 0575
- Downstream MH
- C 0641
- Dir. of Survey
- Downstream
- Length Surveyed
- 179 ft.
- Total Length
- 179 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole C 0575 to C 0641 Observation photos (3)

2 ft. - General Observation - 36" RCP - CIPP

2.8 ft. - General Observation - WHITE BUILD-UP ON LINER

149.8 ft. - Lining Failure Wrinkled, from 03 to 04 o'clock, within 8 inches of joint: NO