Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 19, 2021, 11:34 AM
  • B 0792_B 0791_3192021_043656.mp4

Date
03/19/2021
W/O
0875383
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00112
PipeID
P09259
Time
4:34 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1753
Sewer Name
B JOINT OUTFALL B - UNIT 8J
City
TEMPLE CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
12
Purpose
Routine Assessment
Project
20210319MDM_JOINT_OUTFALL_B_UNIT_8J
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
B 0792
Downstream MH
B 0791
Dir. of Survey
Downstream
Length Surveyed
44.3 ft.
Total Length
44.3 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole B 0792 to B 0791
MH: B 0792MH: B 0791downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:35AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 5 %of cross sectional area22.1 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE33 ft. MGO - General Observation - MH B792 12' VCP UNDER WATER CONNECTING TO LARGE LINE33.3 ft. MWL - Water Level, 90 %of cross sectional area33.3 ft. MGO - General Observation - ZOOM 11' TO MH B 79144.3 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM

Observation photos (2)

  • Water Level, 90 %of cross sectional area

    33.3 ft. - Water Level, 90 %of cross sectional area

  • General Observation - ZOOM 11' TO MH B 791

    33.3 ft. - General Observation - ZOOM 11' TO MH B 791

Observations (9)

DistanceCodeObservation
0MWM
33.3MWL
33MGOMH B792 12' VCP UNDER WATER CONNECTING TO LARGE LINE
22.1FCHAIRLINE
0AMH4:35AM
33.3MGOZOOM 11' TO MH B 791
0MGOConn. @ Mh, 3 O' Clock. Active
44.3AMH4:55AM
0MWL

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2021-03-19T04:34:36-07:00
documentation
MARTIN,CASTILLO,RUVALCABA
is_lateral_inspection
false