- Date
- 01/28/2021
- W/O
- 870604
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00459
- PipeID
- P05717
- Time
- 1:02 AM
- Certificate
- U-109-7948
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8511
- Sewer Name
- 05 INGLEWOOD TRUNK #1
- City
- INGLEWOOD
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_870604_TV05042_JAN2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 36 in.
- Upstream MH
- 05 0500
- Downstream MH
- 05 0499A
- Dir. of Survey
- Downstream
- Length Surveyed
- 126.4 ft.
- Total Length
- 126.4 ft.
- Structural Index
- 3
- Structural Quick
- 3A00
- Structural Rating
- 36
- O&M Index
- 2
- O&M Quick
- 2D00
- O&M Rating
- 48
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 84
Pipe schematic from manhole 05 0500 to 05 0499A Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

38.9 ft. - Lining Failure Wrinkled, at 03 o'clock, within 8 inches of joint: YES, Start

85 ft. - Lining Failure Wrinkled, from 08 to 10 o'clock, within 8 inches of joint: YES