Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 5, 2021, 06:24 AM
  • 05 0490_05 0489A_02042021_223135.mp4

Date
02/04/2021
W/O
870604
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00459
PipeID
P05705
Time
10:24 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8466
Sewer Name
05 INGLEWOOD TRUNK #1
City
INGLEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
04
Purpose
Routine Assessment
Project
WO_870604_TV05042_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
24 in.
Upstream MH
05 0490
Downstream MH
05 0489A
Dir. of Survey
Downstream
Length Surveyed
145.2 ft.
Total Length
145.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2E00
O&M Rating
56
Overall Index
2
Overall Quick
Overall Rating
56
Pipe schematic from manhole 05 0490 to 05 0489A
MH: 05 0490MH: 05 0489Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 04900 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2.4 ft. MGO - General Observation - PIPE IS LINED5.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start7.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"23 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"145.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish145.2 ft. AMH - Downstream Manhole, Survey Ends - 05 0489A145.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    5.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
145.2DAGS
5.8DAGS
23TFC
145.2AMH05 0489A
0AMH05 0490
0MWM
7.5TFC
0MWL
145.2MGOCONN @ MH 3 O'CLOCK/ACTIVE
128.1TFC
2.4MGOPIPE IS LINED
75.7TFC

Properties (8)

additional_info
630074020421201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-02-04T22:24:39-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP