Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2021, 07:38 AM
  • 05 0514_05 0513_01272021_000110.mp4

Date
01/26/2021
W/O
870604
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00459
PipeID
P05731
Time
11:38 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8510
Sewer Name
05 INGLEWOOD TRUNK #1
City
INGELWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
WO_870604_TV05042_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
36 in.
Upstream MH
05 0513
Downstream MH
05 0514
Dir. of Survey
Upstream
Length Surveyed
317.8 ft.
Total Length
317.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2L00
O&M Rating
134
Overall Index
2
Overall Quick
Overall Rating
134
Pipe schematic from manhole 05 0513 to 05 0514
MH: 05 0513MH: 05 0514upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 05141.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish25.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 4" - 40% GREASE/OPEN75.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN101.7 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - 70% DEBRIS/UNKNOWN127.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN154.2 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 4", 4" - 70% DEBRIS/UNKNOWN165.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN207.1 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - 40% DEBRIS/UNKNOWN256.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4" - OPEN297.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4" - OPEN315.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start317.8 ft. MWL - Water Level, 25 %of cross sectional area317.8 ft. AMH - Downstream Manhole, Survey Begins - 05 0513317.8 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
216.1TFD70% DEBRIS/UNKNOWN
2DAGS
0MWL
190.1TFOPEN
110.7TFD40% DEBRIS/UNKNOWN
317.8AMH05 0514
0AMH05 0513
151.9TFOPEN
242.5TFOPEN
20.2TFOPEN
163.6TFD70% DEBRIS/UNKNOWN
61.1TFOPEN
315.9DAGS
292.2TFD40% GREASE/OPEN
0MWM

Properties (8)

additional_info
SC411898
custom_field_three
GREASE/DEBRIS
custom_field_two
4
customer
1
datetime
2021-01-26T23:38:33-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP