Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 5, 2021, 10:57 AM
  • 22 0255_22 0254_02052021_030528.mp4

Date
02/05/2021
W/O
870562
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00793
PipeID
P16537
Time
2:57 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8392
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_870562_TV22016_JAN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0255
Downstream MH
22 0254
Dir. of Survey
Downstream
Length Surveyed
111.3 ft.
Total Length
111.3 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
63
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
63
Pipe schematic from manhole 22 0255 to 22 0254
MH: 22 0255MH: 22 0254downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02550 ft. MWL - Water Level, 5 %of cross sectional area3.1 ft. MGO - General Observation - MAG COAT3.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"63.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"66.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"108.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish111.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0254111.3 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK

Observation photos (2)

  • General Observation - MAG COAT

    3.1 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWM
111.3AMH22 0254
0AMH22 0255
0MWL
3.1MGOMAG COAT
108.6SAP
27.2TFC
63.9TF
111.3MGOCONNECTION AT MH, 9 O'CLOCK
3.1SAP
66.7TFC

Properties (6)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2021-02-05T02:57:54-08:00
documentation
PRO PIPE
is_lateral_inspection