Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2021, 11:14 AM
  • 01 0358_01 0357_02012021_032444.mp4

Date
02/01/2021
W/O
870425
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00215
PipeID
P00832
Time
3:14 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8449
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_870425_TV01077_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0357
Downstream MH
01 0358
Dir. of Survey
Upstream
Length Surveyed
312.5 ft.
Total Length
312.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2K00
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
127
Pipe schematic from manhole 01 0357 to 01 0358
MH: 01 0357MH: 01 0358upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 03582.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish88.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES310.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start312.5 ft. AMH - Downstream Manhole, Survey Begins - 02 0357312.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE312.5 ft. MWM - Water Mark, 40 %of cross sectional area312.5 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    224.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
224.3CM
0AMH02 0357
0MGOCOCKROACHES IN MANHOLE
2DAGS
309.9DAGS
312.5AMH01 0358
0MWM
0MWL

Properties (7)

additional_info
630969020121002
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-02-01T03:14:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false