Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2021, 12:52 PM
  • 01 0353_01 0352_02012021_050552.mp4

Date
02/01/2021
W/O
870425
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00215
PipeID
P00827
Time
4:52 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8449
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
FLORENCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_870425_TV01077_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0353
Downstream MH
01 0352
Dir. of Survey
Downstream
Length Surveyed
434.1 ft.
Total Length
434.1 ft.
Structural Index
3
Structural Quick
3M21
Structural Rating
215
O&M Index
2
O&M Quick
2P00
O&M Rating
172
Overall Index
2
Overall Quick
Overall Rating
387
Pipe schematic from manhole 01 0353 to 01 0352
MH: 01 0353MH: 01 0352downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 03530 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start72.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start427 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish432.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish434.1 ft. AMH - Downstream Manhole, Survey Ends - 01 0352434.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    72.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    434.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
434.1AMH01 0352
427CM
0AMH01 0353
2DAGS
434.1MGOCOCKROACHES IN MANHOLE
432.4DAGS
0MWL
0MGOCOCKROACHES IN MANHOLE
72.5CM
0MWM

Properties (7)

additional_info
630969020121002
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-02-01T04:52:32-08:00
documentation
PRO PIPE
is_lateral_inspection
false