Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2021, 06:04 AM
  • A 0852_A 0851_02162021_223235.mp4

Date
02/16/2021
W/O
870569
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00324
PipeID
P08192
Time
10:04 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8485
Sewer Name
A JOA-1A NORTH LONG BEACH INTERCEPTOR
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_870569_TV03038_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
14 in.
Upstream MH
A 0852
Downstream MH
A 0851
Dir. of Survey
Downstream
Length Surveyed
510.6 ft.
Total Length
510.6 ft.
Structural Index
2
Structural Quick
2S00
Structural Rating
202
O&M Index
2
O&M Quick
2S00
O&M Rating
202
Overall Index
2
Overall Quick
Overall Rating
404
Pipe schematic from manhole A 0852 to A 0851
MH: A 0852MH: A 0851downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 08522 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start508 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish508 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish509.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE510 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE510.6 ft. AMH - Downstream Manhole, Survey Ends - A 0851

Observations (10)

DistanceCodeObservation
2DAGS
0MWL
510MGOCONN @ MH 9 O'CLOCK/ACTIVE
508SSS
2SSS
510.6AMHA 0851
509.5MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
508DAGS
0AMHA 0852

Properties (7)

additional_info
630074021621201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-02-16T22:04:10-08:00
documentation
PROPIPE
is_lateral_inspection
false