Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2021, 07:17 AM
  • A 0850_A 0849_02012021_234104.mp4

Date
02/01/2021
W/O
870569
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00324
PipeID
P08190
Time
11:17 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8463
Sewer Name
A JOA-1A NORTH LONG BEACH INTERCEPTOR
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_870569_TV03038_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
14 in.
Upstream MH
A 0850
Downstream MH
A 0849
Dir. of Survey
Downstream
Length Surveyed
735.4 ft.
Total Length
735.4 ft.
Structural Index
2
Structural Quick
2\00
Structural Rating
292
O&M Index
2
O&M Quick
2\11
O&M Rating
293
Overall Index
2
Overall Quick
Overall Rating
585
Pipe schematic from manhole A 0850 to A 0849
MH: A 0850MH: A 0849downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 08500 ft. MWL - Water Level, 30 %of cross sectional area0.1 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start264 ft. RFJ - Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YES733 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish733 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish735.4 ft. AMH - Downstream Manhole, Survey Ends - A 0849

Observations (9)

DistanceCodeObservation
0AMHA 0850
264RFJ
0.1MWM
733DAGS
735.4AMHA 0849
2DAGS
0MWL
2SSS
733SSS

Properties (7)

additional_info
630074020121201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-02-01T23:17:57-08:00
documentation
PROPIPE
is_lateral_inspection
false