Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2021, 09:04 AM
  • A 0848_A 0847_02022021_012648.mp4

Date
02/02/2021
W/O
870569
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00324
PipeID
P08188
Time
1:04 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8463
Sewer Name
A JOA-1A NORTH LONG BEACH INTERCEPTOR
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_870569_TV03038_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
36 in.
Upstream MH
A 0848
Downstream MH
A 0847
Dir. of Survey
Downstream
Length Surveyed
582.2 ft.
Total Length
582.2 ft.
Structural Index
2
Structural Quick
2V00
Structural Rating
232
O&M Index
2
O&M Quick
2Y13
O&M Rating
265
Overall Index
2
Overall Quick
Overall Rating
497
Pipe schematic from manhole A 0848 to A 0847
MH: A 0848MH: A 0847downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 08480.1 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start136 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start151.5 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES209.2 ft. RFJ - Roots Fine Joint, from 11 to 01 o'clock, within 8 inches of joint: YES502.3 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES580 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish580 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish580 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish582.2 ft. AMH - Downstream Manhole, Survey Ends - A 0847

Observations (13)

DistanceCodeObservation
136DAE
2DAGS
209.2RFJ
0.1MWM
582.2AMHA 0847
580DAGS
502.3RFJ
2SSS
151.5RFJ
580DAE
0MWL
580SSS
0AMHA 0848

Properties (7)

additional_info
630074020121201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-02-02T01:04:09-08:00
documentation
PROPIPE
is_lateral_inspection
false