Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2021, 10:11 AM
  • A 0863_A 0862_01292021_022829.mp4

Date
01/29/2021
W/O
870569
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00324
PipeID
P08203
Time
2:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8461
Sewer Name
A JOA-1A NORTH LONG BEACH INTERCEPTOR
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
07
Purpose
Routine Assessment
Project
WO_870569_TV03038_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
14 in.
Upstream MH
A 0863
Downstream MH
A 0862
Dir. of Survey
Downstream
Length Surveyed
438.2 ft.
Total Length
438.2 ft.
Structural Index
2
Structural Quick
2P00
Structural Rating
174
O&M Index
2
O&M Quick
2P00
O&M Rating
174
Overall Index
2
Overall Quick
Overall Rating
348
Pipe schematic from manhole A 0863 to A 0862
MH: A 0863MH: A 0862downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 08630 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start436 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish436 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish438.2 ft. AMH - Downstream Manhole, Survey Ends - A 0862

Observations (9)

DistanceCodeObservation
436DAGS
2DAGS
438.2AMHA 0862
0MWM
2SSS
0MWL
436SSS
0AMHA 0863
0MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
630075012821201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-01-29T02:11:30-08:00
documentation
PROPIPE
is_lateral_inspection
false