Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2021, 09:12 AM
  • 15 0851_15 0850_392021_011944.mp4

Date
03/09/2021
W/O
0875201
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00594
PipeID
P12629
Time
1:12 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Heavy Cleaning
Media Label
H1742R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIEERA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20210309MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
15 0851
Downstream MH
15 0850
Dir. of Survey
Downstream
Length Surveyed
347.3 ft.
Total Length
347.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3112
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0851 to 15 0850
MH: 15 0851MH: 15 0850downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM85 ft. RMC - Roots Medium Connection, from 02 to 03 o'clock, 5 %, within 8 inches of joint: NO134.7 ft. RFC - Roots Fine Connection, from 11 to 01 o'clock, within 8 inches of joint: NO - 4%239.3 ft. RFC - Roots Fine Connection, from 09 to 10 o'clock, within 8 inches of joint: NO - 3%347.3 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (2)

  • Roots Medium Connection, from 02 to 03 o'clock, 5 %, within 8 inches of joint: NO

    85 ft. - Roots Medium Connection, from 02 to 03 o'clock, 5 %, within 8 inches of joint: NO

  • Roots Fine Connection, from 09 to 10 o'clock, within 8 inches of joint: NO - 3%

    239.3 ft. - Roots Fine Connection, from 09 to 10 o'clock, within 8 inches of joint: NO - 3%

Observations (7)

DistanceCodeObservation
85RMC
239.3RFC3%
0MWM
347.3AMH1:45AM
134.7RFC4%
0MWL
0AMH1:20AM

Properties (5)

customer
LACSD
datetime
2021-03-09T01:12:42-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining
PVCP