- Date
- 01/26/2021
- W/O
- 870405
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00687
- PipeID
- P15037
- Time
- 10:39 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8435
- Sewer Name
- 18 LOWER SPRINGS ROAD TRUNK REPLACEMENT
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_870405_TV18109_JAN2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 1191
- Downstream MH
- 18 1192
- Dir. of Survey
- Upstream
- Length Surveyed
- 411.3 ft.
- Total Length
- 411.3 ft.
- Structural Index
- 3
- Structural Quick
- 3O00
- Structural Rating
- 240
- O&M Index
- 2
- O&M Quick
- 2O00
- O&M Rating
- 164
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 404
Pipe schematic from manhole 18 1191 to 18 1192 Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

8.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

411.3 ft. - General Observation - COCKROACHES IN MANHOLE