- Date
- 03/03/2021
- W/O
- 0875105
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00050
- PipeID
- P10348
- Time
- 3:46 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1738
- Sewer Name
- F JOINT OUTFALL F - UNIT 7H
- City
- CERRITOS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 38
- Purpose
- Routine Assessment
- Project
- 20210303MDM_JOINT_OUTFALL_UNIT_7H
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- F 0218
- Downstream MH
- F 0217
- Dir. of Survey
- Downstream
- Length Surveyed
- 411.9 ft.
- Total Length
- 411.9 ft.
- Structural Index
- 3
- Structural Quick
- 3321
- Structural Rating
- 11
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole F 0218 to F 0217 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

119.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

236.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE VGG

357.1 ft. - Water Level, 40 %of cross sectional area