- Date
- 03/02/2021
- W/O
- 0870254
- Weather
- Dry
- Operator/Surveyor
- MMARTIN
- Sewer ID
- Z00315
- PipeID
- P07751
- Time
- 3:24 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1736
- Sewer Name
- A JOA-1A DISTRICT 5 INTERCEPTOR
- City
- GARDENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 20
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210302MDM_JOA_1A_DISTRICT_5_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Upstream MH
- A 1012
- Downstream MH
- A 0514
- Dir. of Survey
- Downstream
- Length Surveyed
- 30.8 ft.
- Total Length
- 30.8 ft.
- Structural Index
- 5
- Structural Quick
- 5241
- Structural Rating
- 14
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole A 1012 to A 0514 Observation photos (3)

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

3.4 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - CIRCUM REBAR