Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2020, 10:42 AM
  • 05 0099_05 0098_12302020_031626.mp4

Date
12/30/2020
W/O
865118
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05389
Time
2:42 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8342
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_865118_TV05373_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
15 in.
Upstream MH
05 0099
Downstream MH
05 0098
Dir. of Survey
Downstream
Length Surveyed
323.9 ft.
Total Length
323.9 ft.
Structural Index
3
Structural Quick
5E3L
Structural Rating
480
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
480
Pipe schematic from manhole 05 0099 to 05 0098
MH: 05 0099MH: 05 0098downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 00990 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start166.7 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES171.2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start323.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH, 9 O'CLOCK323.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish323.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish323.9 ft. AMH - Downstream Manhole, Survey Ends - 05 0098323.9 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK323.9 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

    166.7 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    171.2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
171.2SRV
166.7SRV
0AMH05 0099
0MWM
323.9MGOACTIVE CONNECTION AT MH, 9 O'CLOCK
0MWL
323.9SSS
2.1SAP
323.9SAP
323.9AMH05 0098
323.9MGOCONNECTION AT MH, 3 O'CLOCK
2.1SSS
323.9SRV

Properties (7)

additional_info
630138122920202
custom_field_three
AGG. PROJCTNG./SPALLNG./REINFRCMNT.
custom_field_two
2
customer
1
datetime
2020-12-30T02:42:44-08:00
documentation
PROPIPE
is_lateral_inspection
false