Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 12, 2021, 07:36 PM
  • C 0004A_C 0001B_02122021_115045.mp4

Date
02/12/2021
W/O
870458
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00116
PipeID
P09473
Time
11:36 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7838
Sewer Name
C JOINT OUTFALL C - UNIT 1
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
16
Purpose
Routine Assessment
Project
WO_870458_TV08064_JAN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Width
12 in.
Upstream MH
C 0004A
Downstream MH
C 0001B
Dir. of Survey
Downstream
Length Surveyed
326.8 ft.
Total Length
326.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole C 0004A to C 0001B
MH: C 0004AMH: C 0001Bdownstream0 ft. MWL - Water Level, 65 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 0004A0 ft. MWM - Water Mark, 70 %of cross sectional area112.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 12"300.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"304.8 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 8"326.8 ft. AMH - Downstream Manhole, Survey Ends - C 0001B

Observations (7)

DistanceCodeObservation
304.8TB
0MWL
0AMHC 0004A
0MWM
112.6TBA
326.8AMHC 0001B
300.7TB

Properties (9)

additional_info
630138021221061
custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-02-12T11:36:52-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE
year_laid
33763