Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2021, 10:47 PM
  • C 0028_C 0027_02112021_151810.mp4

Date
02/11/2021
W/O
870458
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00116
PipeID
P09498
Time
2:47 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7837
Sewer Name
C JOINT OUTFALL C - UNIT 1
City
LONG BEACH
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
17
Purpose
Routine Assessment
Project
WO_870458_TV08064_JAN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Width
15 in.
Upstream MH
C 0028
Downstream MH
C 0027
Dir. of Survey
Downstream
Length Surveyed
694.1 ft.
Total Length
694.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2[00
O&M Rating
276
Overall Index
2
Overall Quick
Overall Rating
276
Pipe schematic from manhole C 0028 to C 0027
MH: C 0028MH: C 0027downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 00280 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start428.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 4"488.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4", 4"692 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish694.1 ft. AMH - Downstream Manhole, Survey Ends - C 0027

Observations (8)

DistanceCodeObservation
2DAGS
488.6TFC
0AMHC 0028
0MWM
0MWL
428.1TFA
694.1AMHC 0027
692DAGS

Properties (9)

additional_info
630138021121071
custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-02-11T14:47:32-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
PVC SPIRAL LINER
year_laid
36132