Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2021, 12:23 PM
  • C 0026_C 0025_02012021_044945.mp4

Date
02/01/2021
W/O
870458
Weather
Light Rain
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00116
PipeID
P09496
Time
4:23 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8450
Sewer Name
C JOINT OUTFALL C - UNIT 1
City
WILMINGTON
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
17
Purpose
Routine Assessment
Project
WO_870458_TV08064_JAN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Width
15 in.
Upstream MH
C 0026
Downstream MH
C 0025
Dir. of Survey
Downstream
Length Surveyed
614.2 ft.
Total Length
614.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2W00
O&M Rating
244
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole C 0026 to C 0025
MH: C 0026MH: C 0025downstream0 ft. MGO - General Observation - LINED PIPE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 00260 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start26.6 ft. MGO - General Observation - STEAM IN SEWER612 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish614.2 ft. AMH - Downstream Manhole, Survey Ends - C 0025

Observations (8)

DistanceCodeObservation
612DAGS
0MGOLINED PIPE
26.6MGOSTEAM IN SEWER
0MWL
0AMHC 0026
0MWM
614.2AMHC 0025
2DAGS

Properties (8)

custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-02-01T04:23:55-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE
year_laid
33763