Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2021, 09:14 AM
  • C 0024_C 0023_02022021_012958.mp4

Date
02/02/2021
W/O
870458
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00116
PipeID
P09494
Time
1:14 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7832
Sewer Name
C JOINT OUTFALL C - UNIT 1
City
WILMINGTON
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
17
Purpose
Routine Assessment
Project
WO_870458_TV08064_JAN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Width
15 in.
Upstream MH
C 0024
Downstream MH
C 0023
Dir. of Survey
Downstream
Length Surveyed
617.3 ft.
Total Length
617.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2X00
O&M Rating
248
Overall Index
2
Overall Quick
Overall Rating
248
Pipe schematic from manhole C 0024 to C 0023
MH: C 0024MH: C 0023downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 00240 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start615 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish615.4 ft. DAR - Deposits Attached Ragging, 5 %of cross sectional area, at 10 o'clock, , within 8 inches of joint: NO617.3 ft. AMH - Downstream Manhole, Survey Ends - C 0023

Observation photos (1)

  • Deposits Attached Ragging, 5 %of cross sectional area, at 10 o'clock,  , within 8 inches of joint: NO

    615.4 ft. - Deposits Attached Ragging, 5 %of cross sectional area, at 10 o'clock, , within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
0AMHC 0024
0MWM
615DAGS
0MWL
615.4DAR
617.3AMHC 0023
2DAGS

Properties (9)

additional_info
630138020121201
custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-02-02T01:14:37-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE
year_laid
33763