Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2021, 11:54 AM
  • 05 2591_05 2590_01182021_035841.mp4

Date
01/18/2021
W/O
865008
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01131
PipeID
P25296
Time
3:54 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8380
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
S.LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_865008_TV05127_DEC2020
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2591
Downstream MH
05 2590
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 05 2591 to 05 2590
MH: 05 2591MH: 05 2590downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 2591 S0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observation photos (1)

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observations (4)

DistanceCodeObservation
0MWM
0AMH05 2591 S
0MWL
2MSAVIEW OF D/S SIPHON FROM U/S MH

Properties (8)

additional_info
630075011221201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-01-18T03:54:20-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
38590