Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2021, 06:09 AM
  • 05 2572_05 2571_01132021_222523.mp4

Date
01/13/2021
W/O
865008
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01131
PipeID
P25274
Time
10:09 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8458
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
S.LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_865008_TV05127_DEC2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2572
Downstream MH
05 2571
Dir. of Survey
Downstream
Length Surveyed
386.7 ft.
Total Length
386.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3700
O&M Rating
21
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 05 2572 to 05 2571
MH: 05 2572MH: 05 2571downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 25720 ft. MWL - Water Level, 20 %of cross sectional area351.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start386.7 ft. AMH - Downstream Manhole, Survey Ends - 05 2571386.7 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Finish

Observation photos (1)

  • Deposits Settled Other,  15 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: NO, Start

    351.9 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start

Observations (6)

DistanceCodeObservation
386.7AMH05 2571
0MWM
0AMH05 2572
386.7DSZ
0MWL
351.9DSZ

Properties (8)

additional_info
630075011321201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-01-13T22:09:43-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
38590