Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2021, 02:27 PM
  • 05 2600_05 2599_01222021_064231.mp4

Date
01/22/2021
W/O
865008
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01131
PipeID
P25305
Time
6:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8504
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
S.LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
08
Purpose
Routine Assessment
Project
WO_865008_TV05127_DEC2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2600
Downstream MH
05 2599
Dir. of Survey
Downstream
Length Surveyed
398.2 ft.
Total Length
398.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 2600 to 05 2599
MH: 05 2600MH: 05 2599downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 2600389.5 ft. CM - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES398.2 ft. AMH - Downstream Manhole, Survey Ends - 05 2599

Observation photos (1)

  • Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

    389.5 ft. - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
398.2AMH05 2599
389.5CM
0MWM
0MWL
0AMH05 2600

Properties (8)

additional_info
630138012221002
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-01-22T06:27:18-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
38590