Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2021, 08:54 AM
  • 29 0274_29 0273_01282021_011625.mp4

Date
01/28/2021
W/O
870549
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00550
PipeID
P24182
Time
12:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8460
Sewer Name
29 WEST HILL STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_870549_TV29063_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0273
Downstream MH
29 0274
Dir. of Survey
Upstream
Length Surveyed
252.2 ft.
Total Length
252.2 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
136
Pipe schematic from manhole 29 0273 to 29 0274
MH: 29 0273MH: 29 0274upstream0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 02740 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"3.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"5.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"11.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"65 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"80.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"98.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"108.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"121.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"125.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"151.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"163.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"166.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"205.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start229.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES237.5 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES244.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"247.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.2 ft. MWM - Water Mark, 5 %of cross sectional area252.2 ft. MWL - Water Level, 5 %of cross sectional area252.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0273

Observation photos (6)

  • Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES

    14.7 ft. - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    22.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    29.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    144.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    187.2 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    240.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (25)

DistanceCodeObservation
165.8TFC
85.7TFC
144.1TB
187.2TB
246.9TFC
88.3TF
249TFC
0MWM
46.6TF
126.9TFC
29.9CM
251.7TF
14.7RFJ
100.9TF
0MWL
5.1TFC
154.1TF
22.7CM
252.2ACOM29 0274
171.5TF
7.7TF
130.5TF
252.2CM
240.3TB
0AMH29 0273

Properties (7)

additional_info
SC411973
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-01-28T00:54:52-08:00
documentation
PROPIPE
is_lateral_inspection
false