Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2021, 08:11 AM
  • 29 0689_29 0264_01282021_003855.mp4

Date
01/28/2021
W/O
870549
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00550
PipeID
P24169
Time
12:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8460
Sewer Name
29 WEST HILL STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_870549_TV29063_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0689
Downstream MH
29 0264
Dir. of Survey
Downstream
Length Surveyed
345.3 ft.
Total Length
345.3 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
17
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole 29 0689 to 29 0264
MH: 29 0689MH: 29 0264downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 068930.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"98.7 ft. JOM - Joint Offset Medium102.9 ft. JOM - Joint Offset Medium186.7 ft. CS - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES191.3 ft. FM - Fracture Multiple, from 11 to 09 o'clock, within 8 inches of joint: YES193.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"195.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"227.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES252.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"323.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES327.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"341.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES345.3 ft. AMH - Downstream Manhole, Survey Ends - 29 0264

Observation photos (7)

  • Joint Offset Medium

    98.7 ft. - Joint Offset Medium

  • Joint Offset Medium

    102.9 ft. - Joint Offset Medium

  • Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    186.7 ft. - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 09 o'clock, within 8 inches of joint: YES

    191.3 ft. - Fracture Multiple, from 11 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    227.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    323.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    341.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
252.8TFC
30.4TFC
0MWL
345.3AMH29 0264
341.1CM
294.7TFC
195.8TFC
323.4CM
98.7JOM
0MWM
186.7CS
102.9JOM
74.5TF
227.1CM
0AMH29 0689
191.3FM
327.6TF
193.3TF

Properties (7)

additional_info
SC411973
custom_field_three
MULTIPLE CRACKS/FRACTURE
custom_field_two
3
customer
1
datetime
2021-01-28T00:11:05-08:00
documentation
PROPIPE
is_lateral_inspection
false