Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2021, 10:54 AM
  • 22 0280_22 0279_02032021_030948.mp4

Date
02/03/2021
W/O
870414
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00793
PipeID
P16566
Time
2:54 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8389
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_870414_TV22014_JAN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0280
Downstream MH
22 0279
Dir. of Survey
Downstream
Length Surveyed
239.7 ft.
Total Length
239.7 ft.
Structural Index
3
Structural Quick
413H
Structural Rating
145
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
145
Pipe schematic from manhole 22 0280 to 22 0279
MH: 22 0280MH: 22 0279downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02800 ft. MGO - General Observation - CONNECTION AT MH, 3 & 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. MGO - General Observation - MAG COAT2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start34.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"70.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"94.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"123.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"150.4 ft. FM - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES196.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"238.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish239.7 ft. AMH - Downstream Manhole, Survey Ends - 22 0279

Observation photos (3)

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

    150.4 ft. - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
239.7AMH22 0279
2MGOMAG COAT
123.2TFC
0MWM
2SAP
70.2TFC
0AMH22 0280
34.2TFC
196.2TFC
0MGOCONNECTION AT MH, 3 & 9 O'CLOCK
150.4FM
94.7TFC
0MWL
238.8SAP

Properties (6)

custom_field_three
AGGREGATE PROJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2021-02-03T02:54:54-08:00
documentation
PRO PIPE
is_lateral_inspection
false