Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2021, 07:08 AM
  • 18 0331_18 0326_01272021_231946.mp4

Date
01/27/2021
W/O
870457
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00684
PipeID
P14165
Time
11:08 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8439
Sewer Name
18 LA MIRADA TRUNK, SECTION 3
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
WO_870457_TV18024_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0331
Downstream MH
18 0326
Dir. of Survey
Downstream
Length Surveyed
287.6 ft.
Total Length
287.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412J
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
118
Pipe schematic from manhole 18 0331 to 18 0326
MH: 18 0331MH: 18 0326downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 03312 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start9.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"29.9 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"81.2 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"91.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.8 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"228.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"248.7 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"287.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish287.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK287.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE287.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0326

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    287.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (16)

DistanceCodeObservation
287.6MGOCONNECTION AT MH 9 O'CLOCK
147.8TFA
287.6MGOCOCKROACHES IN MANHOLE
248.7TFA
0MWL
142.1TFA
91.5TFA
0MWM
2DAGS
81.2TFA
287.2DAGS
29.9TFA
9.2TFA
228.3TFC
0AMH18 0331
287.6AMH18 0326

Properties (7)

additional_info
630069012721201
custom_field_three
LIGHT GREASE/RFIR
custom_field_two
3
customer
1
datetime
2021-01-27T23:08:17-08:00
documentation
PRO PIPE
is_lateral_inspection
false