- Date
- 01/27/2021
- W/O
- 870457
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00684
- PipeID
- P14165
- Time
- 11:08 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8439
- Sewer Name
- 18 LA MIRADA TRUNK, SECTION 3
- City
- LA MIRADA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- WO_870457_TV18024_JAN2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0331
- Downstream MH
- 18 0326
- Dir. of Survey
- Downstream
- Length Surveyed
- 287.6 ft.
- Total Length
- 287.6 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 412J
- O&M Rating
- 118
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 118
Pipe schematic from manhole 18 0331 to 18 0326 Observation photos (2)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

287.6 ft. - General Observation - COCKROACHES IN MANHOLE