- Date
- 02/18/2021
- W/O
- 0875039
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00498
- PipeID
- P05509
- Time
- 1:28 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1724
- Sewer Name
- 05 OAK STREET-CENTER AVENUE TRUNK
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 06
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210217MDM_OAK_STREET_CENTER_AVENUE_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 22 in.
- Upstream MH
- 05 0301
- Downstream MH
- 05 0300
- Dir. of Survey
- Downstream
- Length Surveyed
- 329.9 ft.
- Total Length
- 329.9 ft.
- Structural Index
- 3
- Structural Quick
- 4132
- Structural Rating
- 14
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 05 0301 to 05 0300 Observation photos (5)

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

40.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

93 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

212.6 ft. - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - ROCK